<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE ArticleSet PUBLIC "-//NLM//DTD PubMed 2.7//EN" "https://dtd.nlm.nih.gov/ncbi/pubmed/in/PubMed.dtd">
<ArticleSet>
<Article>
<Journal>
				<PublisherName>Institute for Color Science and Technology (ICST)</PublisherName>
				<JournalTitle>Progress in Color, Colorants and Coatings</JournalTitle>
				<Issn>2008-2134</Issn>
				<Volume>15</Volume>
				<Issue>3</Issue>
				<PubDate PubStatus="epublish">
					<Year>2022</Year>
					<Month>07</Month>
					<Day>01</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Corrosion Inhibition Activity of Cefixime on Mild Steel Surface in Aqueous Sulphuric Acid</ArticleTitle>
<VernacularTitle></VernacularTitle>
			<FirstPage>243</FirstPage>
			<LastPage>255</LastPage>
			<ELocationID EIdType="pii">81808</ELocationID>
			
<ELocationID EIdType="doi">10.30509/pccc.2021.166889.1133</ELocationID>
			
			<Language>EN</Language>
<AuthorList>
<Author>
					<FirstName>S.</FirstName>
					<LastName>TANWER</LastName>
<Affiliation>Department of Chemistry, Manav Rachna University, Faridabad-221004, Haryana India.</Affiliation>

</Author>
<Author>
					<FirstName>S. Kumar</FirstName>
					<LastName>Shukla</LastName>
<Affiliation>Department of Chemistry, Manav Rachna University, Faridabad-221004, Haryana India.</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2021</Year>
					<Month>09</Month>
					<Day>06</Day>
				</PubDate>
			</History>
		<Abstract>&lt;em&gt;Interaction of pharmaceutically active drug Cefixime on mild steel surface in 0.5 M sulphuric acid solution was studied using gravimetric analysis techniques, Polarization techniques, i.e., Polarization resistance, Tafel polarization, and Electrochemical Impedance Spectroscopy (EIS) techniques.&lt;strong&gt; &lt;/strong&gt;It shows more than 96 % corrosion inhibition efficiency at an ambient temperature of 308 &lt;sup&gt;o&lt;/sup&gt;K on a mild steel surface with a 4.0×10&lt;sup&gt;-4 &lt;/sup&gt;M  inhibitor concentration. Gravimetric studies were also conducted at various temperatures and concentration ranges of the testing solution to justify their range of applicability at different practical conditions. And It is found very much suitable for its workings at the normal temperature and lower acid concentration ranges. Adsorption parameters and thermodynamic parameters were calculated from gravimetric analysis data. These parameters were obtained at different temperatures and concentration ranges and reveal that the inhibitor follows the physical adsorption mechanism. Langmuir&#039;s adsorption isotherm governs the adsorption of the cefixime molecule. Inhibition of cefixime on the surface of mild steel is supplemented by atomic force microscopy. The result reveals that the inhibited surface has less roughness than the uninhibited surface.&lt;/em&gt;</Abstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">gravimetric analysis</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Tafel polarization</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">EIS technique</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">cephalosporin antibiotic</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://pccc.icrc.ac.ir/article_81808_1202fb7b9c4aa3bb38ab2a5152017319.pdf</ArchiveCopySource>
</Article>
</ArticleSet>
